United States
Select country
  • Europe
  • North America
  • South America
  • Asia / Pacific
  • Middle East / Africa

Vision

vision

Information
Technical data
Compliance
Applications
Download
Type 2, SILCL1, PL c, Cat.2 safety light curtain

The VISION Type 2 family of safety light curtains is the ideal solution for the protection of the majority of industrial applications in Category 2.

Test function, activated automatically and periodically, without interruption of the operation of the machine being controlled.

The breadth of the range, including Master / Slave models for cascade connection of two in Muting function.

Vision light curtains may be connected to the dedicated safety interfaces series AD SR, or directly to contactors actuated and controlled by the light curtain, or to MOSAIC or to suitable commercial safety modules or safety PLCs.

Safety levelType 2 according to IEC 61496-1; IEC 61496-2
SILCL 1 according to IEC 62061
PL c - Cat. 2 according to EN ISO 13849-1
Safety outputs2 PNP auto-controlled - 500 mA at 24 VDC with short-circuit, overload, polarity reversal protection
SignallingLEDs for light curtain's status and diagnostic
Power supply (VDC)24 +/-20%
Max. cable length (m)100
Operating temperature (°C)0 ... +55
Protection rateIP 65
Fastening modesBack slot, side slot or to the top and lower end with swivel brackets
Cross section (mm)35 x 45
  • 2006/42/EC: Machine Directive
  • 2014/30/EU: Electromagnetic Compatibility Directive
  • 2014/35/EU: Low Voltage Directive
  • IEC 61496-1 (ed. 3) Safety of machinery. Electro sensitive protective equipment. General requirements and tests
  • IEC 61496-2 (ed. 3) Safety of machinery. Electro-sensitive protective equipment. Particular requirements for equipment using active opto-electronic protective devices (AOPDs)
  • IEC 62061 (ed. 1) (SILCL 1) Safety of machinery. Functional safety of safety-related electrical, electronic and programmable electronic control systems
  • EN ISO 13849-1:2008 (Cat. 2, PL c) Safety of machinery. Safety-related parts of control systems. Part 1: General principles for design
  • EN 50178:1997 Electronic equipment for use in power installations
  • EN 55022:2010 Information Technology Equipment. Radio Disturbance Characteristics. Limits and Methods of Measurement
  • UL (C+US) mark for USA and Canada
  • ANSI / UL 1998: Safety Software in Programmable Components
Certifications:
  • Palletisers and depalletisers
  • Handling and storage systems
  • Assembly and disassembly lines
  • Robotised areas
  • Wood and marble processing machines
  • Welding systems and robots
  • Long distance protection and perimetre protection using defection mirrors (SP and FMC columns)

Note: where the risk analysis allows the use of category 2 safety equipment

Selettore - VISION

Range

VISION V L

With automatic Start/Restart

VISION V H

High range models with automatic Start/Restart

VISION VX

With built-in control functions

VISION VX LR

High range models with built-in control function

VISION VXM - VXS

Master/Slave models with built-in control functions

VISION VXL

Entry level with built-in control function

VISION MXL - MXL

With integrated Muting function

VISION MXL L

With 2 integrated photoelectric Muting sensors with crossed beams - Only exit access control

VISION MXL T

With 2 integrated photoelectric Muting sensors with crossed beams - Entry/Exit access control

VISION VX WT/WTH

IP 67 watertight enclosure

Selector

Detection

Finger

Hand

Body

Access control

Light curtain model

ADMIRAL

EOS2

EOS4

JANUS

VISION

SAFEGATE

Resolution (mm)

14

20

30

40

50

90

Number of beams

2

3

4

Safety level

Type 2

Type 4

Height of protected area (mm)

160-460

461-910

911-1360

1361-1560

1561-1810

1811-2260

Max. range (m)

< 10

10-20

> 20

Muting Function

Built-in

Built-in with horizontal arms

With external modules

Enclosures

Harsh working environments

Food industry IP 69K

ATEX zone 2, 22

None

Safety functions

Integrated

With external module

Blanking function

Floating

No

Operating temperature (°C)

From -30 to 55

From -20 to 55

From -10 to 55

From 0 to 55

From -25 to 50

Reset

Selected Models

Model Resolution Beams Protected area Max. range Safety level Code