Poland
Select country
  • Europe
  • North America
  • South America
  • Asia / Pacific
  • Middle East / Africa

SAFEGATE

SAFEGATE

Information
Technical data
Compliance
Applications
Download
Safety light curtain with integrated muting functions

The new SAFEGATE type 4 range of safety light curtains is the ideal solution for the protection of a vast number of high-risk industrial applications, in particular those requiring a highlevel of integration of the muting functions.

SAFEGATE guarantees the integration of the muting sensors that can be connected directly to the safety light curtain.

  • Hardware configurable models (SM/SMO) allow configuration of the muting logic and functional parameters via the main connector wiring
  • Programmable models (SMPO) functional parameters configuration is managed instead via Safegate Configuration Software (SCS)

YOUTUBE ENG

Safety levelType 4 according to EN 61496-1; IEC 61496-2
SIL 3 according to IEC 61508
SILCL 3 according to IEC 62061
PL e Cat. 4 according to EN ISO 13849-1
Protected heights300 mm ... 2200 mm
Risolution30 and 40 mm - 2, 3 and 4 beams
VersionsEmitter/receiver
Transreceiver versionPassive retro-reflector elements
Safety functionsStatic outputs
EDM
Start/Restart Interlock
Cross-section dimensions55 x 50 mm
Protection ratingIP 65 e IP 67
Operating temperature (°C)-30 ... 55 (without condensing)
Muting lampIntegratd (optional)
  • 2006/42/EC: Machine Directive
  • 2014/30/EU: Electromagnetic Compatibility Directive
  • 2014/35/EU: Low Voltage Directive
  • EN 61496-1:2013 (Type 4) Safety of machinery. Electro-sensitive protective equipment. General requirements and tests
  • EN 61496-2:2013 (Type 4) Safety of machinery. Electro-sensitive protective equipment. Particular requirements for equipment using active opto-electronic protective devices (AOPDs)
  • EN 61508-1:2010 (SIL 3) Functional safetyof electrical/electronic programmable electronic safety related systems. General requirements
  • EN 61508-2:2010 (SIL 3) Functional safety of electrical/electronic/programmable electronic safety related systems. Requirements for electrical/electronic/programmable electronic safety-related systems
  • EN 61508-3:2010 (SIL 3) Functional safety of electrical/electronic programmable electronic safety related systems. Software requirements
  • EN 61508-4:2010 (SIL 3) Functional safety of electrical/electronic programmable electronic safety related systems. Definitions and abbreviations
  • EN 62061:2005/A2:2015 (SILCL 3) Safety of machinery. Functional safety of safety-related electrical, electronic and programmable electronic control systems
  • EN ISO 13849-1:2015 (Cat. 4, PL e) Safety of machinery. Safety-related parts of control systems. Part 1: General principles for design
  • UL (C+US) mark for USA and Canada
  • ANSI / UL 1998: Safety Software in Programmable Components
Certifications:
  • Palletizers
  • Robotized areas
  • Assembly lines
  • Automatic industrial warehouses
  • Areas through which AGV automatically guided vehicles pass
  • Access control
  • Cutting machines
  • Robot-palletisers
  • Automatic punching machines
  • Shear lines

Muting applications

  • "L" Logic Crossed beams
    Suitable solution for any applications of pallet exit
  • "L" Logic Parallel beams
    Suitable solution for transparent material: glass and bottling industry of pallet exit
  • "T" Logic Crossed beams
    Suitable solution for the most common pallet infeed/outfeed applications
    Ideal solution in case of a continuous flow of pallets even without separation between the pallets
  • "T" Logic Parallel beams
    Suitable solution for transparent material and application with presence of a pallet with reduced width or not centred with respect to the conveyor. Through the verification of the 4 sensors, allows to set infinite muting time-out
    Please note: this configuration needs a separation between two consecutive pallets equal to the distance between the two external muting sensors

Selettore - SAFEGATE

Range

SAFEGATE SM

Hardware configuration

SAFEGATE SMO

Hardware configuration with integrated muting lamp

SAFEGATE SMPO

Programmable with integrated Muting lamp

MUTING ACCESSORY KITS

Arms and brackets for Muting sensors

Selector

Detection

Finger

Hand

Body

Access control

Light curtain model

ADMIRAL

EOS2

EOS4

JANUS

VISION

SAFEGATE

Resolution (mm)

14

20

30

40

50

90

Number of beams

2

3

4

Safety level

Type 2

Type 4

Height of protected area (mm)

160-460

461-910

911-1360

1361-1560

1561-1810

1811-2260

Max. range (m)

< 10

10-20

> 20

Muting Function

Built-in

Built-in with horizontal arms

With external modules

Enclosures

Harsh working environments

Food industry IP 69K

ATEX zone 2, 22

None

Safety functions

Integrated

With external module

Blanking function

Floating

No

Operating temperature (°C)

From -30 to 55

From -20 to 55

From -10 to 55

From 0 to 55

From -25 to 50

Reset

Selected Models

Model Resolution Beams Protected area Max. range Safety level Code