Safety light curtains Master (XM)


Items per page

Showing 1–12 of 61 results

1321206

Master, Auto-manual restart + EDM

Safety level

Type 2 – PL c

Protected height (mm)

260

Resolution (mm)

30

Max. range (m)

12

Restart

Built-in – User selectable automatic or manual

Master, Auto-manual restart + EDM

Safety level Protected height (mm) Resolution (mm) Max. range (m) Restart

Type 2 – PL c

260

30

12

Built-in – User selectable automatic or manual

1320221

Master, Auto-manual restart + EDM

Safety level

Type 2 – PL c

Protected height (mm)

310

Resolution (mm)

30

Max. range (m)

12

Restart

Built-in – User selectable automatic or manual

Master, Auto-manual restart + EDM

Safety level Protected height (mm) Resolution (mm) Max. range (m) Restart

Type 2 – PL c

310

30

12

Built-in – User selectable automatic or manual

1320222

Master, Auto-manual restart + EDM

Safety level

Type 2 – PL c

Protected height (mm)

460

Resolution (mm)

30

Max. range (m)

12

Restart

Built-in – User selectable automatic or manual

Master, Auto-manual restart + EDM

Safety level Protected height (mm) Resolution (mm) Max. range (m) Restart

Type 2 – PL c

460

30

12

Built-in – User selectable automatic or manual

1320223

Master, Auto-manual restart + EDM

Safety level

Type 2 – PL c

Protected height (mm)

610

Resolution (mm)

30

Max. range (m)

12

Restart

Built-in – User selectable automatic or manual

Master, Auto-manual restart + EDM

Safety level Protected height (mm) Resolution (mm) Max. range (m) Restart

Type 2 – PL c

610

30

12

Built-in – User selectable automatic or manual

1320224

Master, Auto-manual restart + EDM

Safety level

Type 2 – PL c

Protected height (mm)

760

Resolution (mm)

30

Max. range (m)

12

Restart

Built-in – User selectable automatic or manual

Master, Auto-manual restart + EDM

Safety level Protected height (mm) Resolution (mm) Max. range (m) Restart

Type 2 – PL c

760

30

12

Built-in – User selectable automatic or manual

1320225

Master, Auto-manual restart + EDM

Safety level

Type 2 – PL c

Protected height (mm)

910

Resolution (mm)

30

Max. range (m)

12

Restart

Built-in – User selectable automatic or manual

Master, Auto-manual restart + EDM

Safety level Protected height (mm) Resolution (mm) Max. range (m) Restart

Type 2 – PL c

910

30

12

Built-in – User selectable automatic or manual

1320226

Master, Auto-manual restart + EDM

Safety level

Type 2 – PL c

Protected height (mm)

1060

Resolution (mm)

30

Max. range (m)

12

Restart

Built-in – User selectable automatic or manual

Master, Auto-manual restart + EDM

Safety level Protected height (mm) Resolution (mm) Max. range (m) Restart

Type 2 – PL c

1060

30

12

Built-in – User selectable automatic or manual

1320227

Master, Auto-manual restart + EDM

Safety level

Type 2 – PL c

Protected height (mm)

1210

Resolution (mm)

30

Max. range (m)

12

Restart

Built-in – User selectable automatic or manual

Master, Auto-manual restart + EDM

Safety level Protected height (mm) Resolution (mm) Max. range (m) Restart

Type 2 – PL c

1210

30

12

Built-in – User selectable automatic or manual

1320228

Master, Auto-manual restart + EDM

Safety level

Type 2 – PL c

Protected height (mm)

1360

Resolution (mm)

30

Max. range (m)

12

Restart

Built-in – User selectable automatic or manual

Master, Auto-manual restart + EDM

Safety level Protected height (mm) Resolution (mm) Max. range (m) Restart

Type 2 – PL c

1360

30

12

Built-in – User selectable automatic or manual

1320229

Master, Auto-manual restart + EDM

Safety level

Type 2 – PL c

Protected height (mm)

1510

Resolution (mm)

30

Max. range (m)

12

Restart

Built-in – User selectable automatic or manual

Master, Auto-manual restart + EDM

Safety level Protected height (mm) Resolution (mm) Max. range (m) Restart

Type 2 – PL c

1510

30

12

Built-in – User selectable automatic or manual

1320274

Master, Auto-manual restart + EDM

Safety level

Type 2 – PL c

Protected height (mm)

1660

Resolution (mm)

30

Max. range (m)

12

Restart

Built-in – User selectable automatic or manual

Master, Auto-manual restart + EDM

Safety level Protected height (mm) Resolution (mm) Max. range (m) Restart

Type 2 – PL c

1660

30

12

Built-in – User selectable automatic or manual

1320275

Master, Auto-manual restart + EDM

Safety level

Type 2 – PL c

Protected height (mm)

1810

Resolution (mm)

30

Max. range (m)

12

Restart

Built-in – User selectable automatic or manual

Master, Auto-manual restart + EDM

Safety level Protected height (mm) Resolution (mm) Max. range (m) Restart

Type 2 – PL c

1810

30

12

Built-in – User selectable automatic or manual

Safety distance calculator Safety distance calculator