Available models
Model | Description | Code |
---|
The Ilion photocells must be connected to control unit for esample: standard AU SX or AU SXM control unit with Muting or Mosaic to form a protection system that can be composed of 1, 2, 3 or 4 single beam photocells.
In case of connection with Mosaic safety controller, the number of photocells depends to the configuration of the protection system. (For details on the interface see AU SX, AU SXM and Mosaic control units).
Safety level | Type 2 according to IEC 61496-1 |
Minimum detectable object (mm) | 12 |
Max range (m) | 8 - IL 10 20 - IL 20 |
Number of photocells per control unit | 1 ... 4 with AU SX and AU SXM control units In case of the Mosaic safety controller the number of photocells depends to the number available input related to the system configuration |
Response time for each photocell (ms) | 7 |
Output | PNP - 100 mA |
signalling | LED status |
Power supply (VDC) | 24 ± 20% |
Electricalconnections | M12 4-pole |
Max. cable length (m) | 50 (between sensor and control unit) |
Operating temperature (°C) | 0 ... 55 |
Protection rating | IP 67 |
Dimensions (mm) | Ø 18 x 85 |
Note: where the risk analysis allows the use of category 2 safety equipment.
Technical manuals
Catalogues and Brochures
Model | Description | Code |
---|