Configurable Safety Controllers and Interfaces

Safety controllers are capable of monitoring several safety sensors and commands, such as safety light curtains, laser scanners, photocells, mechanical switches, mats, emergency stops, two-hand controls, concentrating management of these in a single, flexible device.

Safety interfaces are a dedicated interfaces between safety devices equipped with self-controlled safety static outputs and control circuits of the machine or plant.



Fam_MOSAIC_M1S

Main characteristics

Discover our safety controllers and interfaces

Mosaic is a Safety controller able to manage all Safety functions of machinery. It is configurable and scalable by providing cost reductions and minimal wiring.
Compact and configurable Safety controller. Bringing full configuration capabilities at the cost of a standard Safety relay.
Dedicated Safety interfaces between Safety sensors equipped with self-controlled Safety static outputs and control circuits of the machine or plant. Modules for Safety light curtains, Safety switches, two-hand controls and e-stops

CHARACTERISTICS

CHARACTERISTICS

CHARACTERISTICS

SYSTEM CAPABILITIES

Digital input

DIGITAL INPUTS

Up tp 128
Analogue input

ANALOGUE INPUTS

Up to 16 (with expansion)
Safety output

SAFETY OUTPUTS

Up to 32 (SIL 3)
Safety output

STATUS OUTPUTS

Up to 48 (SIL 1)
Relay

SAFETY RELAY OUTPUT

Up to 32 (with expansion)
Logical operators

LOGICAL OPERATORS

128

SYSTEM CAPABILITIES

Digital input

DIGITAL INPUTS

16
Analogue input - not available

ANALOGUE INPUTS

-
Safety output

SAFETY OUTPUTS

4 (SIL 3)
Safety output

STATUS OUTPUTS

4 (SIL 1)
Relay

SAFETY RELAY OUTPUT

Up to 4 (with expansion)
Logical operators

LOGICAL OPERATORS

64

INTERFACES

Relay

AD SR0 - AD SR0A

2 NO + 1 NC
2 NO
Relay

AD SRE3 - AD SR3 C

3 NO + 1 NC - Automatic/Manual restart
3 NO + 1 NC - Manual restart
Relay

AD SRE4 - AD SRE4C

3 NO + 1 NC - Automatic/manual restart
3 NO + 1 NC - Manual restart
Relay

AD SRT

2 NO + 1 NC
Encorders

SV MR0 - Speed monitoring

2 NO
Encorders

SV MR0 U - Speed monitoring

2 NO

ESPANSION UNITS

Safety relay

Safety relay

Relay
Safety speed monitoring

Safety speed monitoring

Encorders
Analogue sensors

Analogue sensors

Analogue input
Industrial fieldbus

Industrial fieldbus

Field bus
High-current output

High-current output

High current outputs

ESPANSION UNITS

Safety relay

Safety relay

Relay
Safety speed monitoring

Safety speed monitoring

Encorders - not available
Analogue sensors

Analogue sensors

Analogue input - not available
Industrial fieldbus

Industrial fieldbus

Field bus - not available
High-current output

High-current output

High current outputs -not available

INTERFACES

Relay

SR SELECT

2 NO
Relay

SR ZERO - SR ZERO A

2 NO + 1 NC
2 NO
Relay

SR ONE - SR ONE M

2 NO
2 NO - Muting function
Relay

SR E4 - SR E4 C

2 NO - Automatic/manual restart
2 NO - Manual restart
Relay

SR T

2 NO
Relay

SR X - SR XM

2 NO
2 NO - Muting function

FASTENING

Brackets

DIN RAIL

TERMINAL BLOCKS

Terminal block

Screws, Clamps

FASTENING

Brackets

DIN RAIL

TERMINAL BLOCKS

Terminal block

Screws, Clamps

FASTENING

Brackets

DIN RAIL

TERMINAL BLOCKS

Terminal block

Screws, Clamps

SAFETY LEVEL

Safety level

PL e - SILCL 3 - Cat. 4

IP RATING

IP rating

IP20

SAFETY LEVEL

Safety level

PL e - SILCL 3 - Cat. 4

IP RATING

IP rating

IP20

SAFETY LEVEL

Safety level

PL e - SILCL 3 - Cat. 4

IP RATING

IP rating

IP20