Available models
| Model | Description | Code |
|---|

AU SXM control unit, with integrated Muting functions, for safety photocells Ilion and Ulisse, which can be combined to form a Type 2 safety system. Up to 4 photocells may be connected.
The AU SXM interface works with 2 Muting sensors with contemporary logic and is equipped with:
Other integratet functions
| Number of photocells | 1 ... 4 |
| Inputs for Muting sensors | 2 inputs 0 or 24 VDC PNP or relay (dark on) |
| Muting Enable input | 0 or 24 VDC PNP or relay (dark on) |
| Safety relay outputs | 2 N.O. - 2A 250 VAC |
| Status output | PNP - 100 mA at 24 VDC |
| Muting lamp output | 24 VDC - 0,5 ... 5 W |
| Response time (ms) | <= 30 |
| Start/Restart command | Manual or automatic. Start/Restart selectable on terminal block |
| External relay control | Yes - EDM feedback input for external contactors monitoring |
| Signalling | LED indications of input/output status, Muting sensor inputs, diagnosis |
| Muting time-out | 30 sec. or infinite, selectable |
| Override | 2 operating modes selectable: - Manual action with hold to run - Automatic with pulse command |
| Override time-out (min.) | 15 |
| Power supply (VDC) | 24 ± 20% |
| Electrical connections | On terminal block |
| Operating temperature (°C) | 0 ... 55 |
| Protection rating | IP 20 for housing - IP 2X for terminal block |
| Fastening | On DIN rail fastening according to EN 50022-35 standard |
| Dimensions h x w x d (mm) | 99 x 35 x 114 |
| Model | Description | Code |
|---|