Range
Available models
Model | Height of controlled area | Beam spacing | Beams | Code |
---|
Light curtains for industrial and civil applications where it is necessary to detect,measure, and recognise objects.
Depending on the number and position of the beams engaged by an object, Micron can provide real time information to a PLC or PC in order to: detect the presence or absence of objects, perform a count, detect a position, detect ashape or a profile, measure dimensions.
MicronConfigurator software for PC, with graphic user interface, is supplied with each light curtain (models A and B only). Models A and B are provided with an M5 4-pole connector for parameter configuration and monitoring ofthe light curtain.
Beams spacing available: 5, 10, 25, 30 , 50 and 75 mm.
Controlled heights: 150 mm ... 3000 mm - models with beams spacing 10, 25, 30, 50, 75 mm; 150 mm ... 1500 mm - models with beams spacing 5 mm.
Max. range:
Connections with M12 connectors. Possibility of connection of up to 3 Micron B light curtains as nodes of an RS-485 serial line for simultaneous detection of multiple dimensions and complex measurements.
Single-beam retro-reflector photocells and Multibeams photocells used as Muting sensors
Controlled heights (mm) | 150 mm ... 3000 mm - models with beams spacing 10, 25, 30, 50 and 75 mm 150 mm ...1500 mm - models with beams spacing 5 mm |
Beams spacing (mm) | 5, 10, 25, 30, 50, 75 |
Max. range | 2,5 m - models with beams spscing 5 mm 6 m - special models with beams spacing 25, 50, 75 mm for automatic warehouses 10 m - models with beams spacing 10, 30 mm 18 m - models with beams spacing 25, 50, 75 mm |
Measurement time | (500 µs + 70 µs x n beams) x N Where N=scan cycles (1,2,3 selectable) |
Synchronisation between emitter and receiver | Optical or via cable, selectable |
Signalling | LEDs for operating status and light curtain self-diagnosis |
Power supply VDC | 24 +/- 20% |
Max. length connection cables between light curtain and interface (m) | 100 |
Operating temperature (°C) | -10 ... + 55 |
Protection rating | IP 65 and IP 67 |
Fastening mode | Back slot, or to the top and lower end with SFB E180 rotatingbrackets (optional) |
Cross-section dimensions (mm) | 28 x 30 |
Technical manuals
IT - MICRON - Instructions manual
IT - M5H Photocell - INSTRUCTION SHEET
IT - M5 Photocell - INSTRUCTION SHEET
IT - MTRX Photocell - INSTRUCTION SHEET
EN - MICRON - Instructions manual
EN - M5H Photocell - INSTRUCTION SHEET
EN - MICRON IOL - Instructions manual
EN - M5 Photocell - INSTRUCTION SHEET
EN - MTRX Photocell - INSTRUCTION SHEET
DE - MICRON - Instructions manual
ES - MICRON - Instructions manual
Catalogues and Brochures
Model | Height of controlled area | Beam spacing | Beams | Code |
---|