Configurable Safety Controllers and Interfaces

Safety controllers are capable of monitoring several safety sensors and commands, such as safety light curtains, laser scanners, photocells, mechanical switches, mats, emergency stops, two-hand controls, concentrating management of these in a single, flexible device.

Safety interfaces are a dedicated interfaces between safety devices equipped with self-controlled safety static outputs and control circuits of the machine or plant.



Main characteristics

Controllers and Interfaces characteristics

Mosaic is a safety controller able to manage all safety functions of machinery. It is configurable and scalable by providing cost reductions and minimal wiring.
Compact and configurable safety controller. Bringing full configuration capabilities at the cost of a standard safety relay.
Dedicated safety interfaces between safety sensors equipped with self-controlled safety static outputs and control circuits of the machine or plant. Modules for safety light curtains, safety switches, two-hand controls and e-stops

CHARACTERISTICS

CHARACTERISTICS

CHARACTERISTICS

SYSTEM CAPABILITIES

DIGITAL INPUTS

DIGITAL INPUTS

Up tp 128
ANALOGUE INPUTS

ANALOGUE INPUTS

Up to 16 (with expansion)
SAFETY OUTPUTS

SAFETY OUTPUTS

Up to 32 (SIL 3)
STATUS OUTPUTS

STATUS OUTPUTS

Up to 48 (SIL 1)
SAFETY RELAY OUTPUT

SAFETY RELAY OUTPUT

Up to 32 (with expansion)
LOGICAL OPERATORS

LOGICAL OPERATORS

128

SYSTEM CAPABILITIES

DIGITAL INPUTS

DIGITAL INPUTS

16
ANALOGUE INPUTS

ANALOGUE INPUTS

-
SAFETY OUTPUTS

SAFETY OUTPUTS

4 (SIL 3)
STATUS OUTPUTS

STATUS OUTPUTS

4 (SIL 1)
SAFETY RELAY OUTPUT

SAFETY RELAY OUTPUT

Up to 4 (with expansion)
LOGICAL OPERATORS

LOGICAL OPERATORS

64

INTERFACES

AD SR0 - AD SR0A

AD SR0 - AD SR0A

2 NO + 1 NC
2 NO
AD SRE3 - AD SR3 C

AD SRE3 - AD SR3 C

3 NO + 1 NC - Automatic/Manual restart
3 NO + 1 NC - Manual restart
AD SRE4 - AD SRE4C

AD SRE4 - AD SRE4C

3 NO + 1 NC - Automatic/manual restart
3 NO + 1 NC - Manual restart
AD SRT

AD SRT

2 NO + 1 NC
SR SELELCT

SR SELELCT

2 NO

ESPANSION UNITS

Safety relay

Safety relay

Safety relay
Safety speed monitoring

Safety speed monitoring

Safety speed monitoring
Analogue sensors

Analogue sensors

Analogue sensors
Industrial fieldbus

Industrial fieldbus

Industrial fieldbus
High-current output

High-current output

High-current output

ESPANSION UNITS

Safety relay

Safety relay

Safety relay
Safety speed monitoring

Safety speed monitoring

Safety speed monitoring
Analogue sensors

Analogue sensors

Analogue sensors
Industrial fieldbus

Industrial fieldbus

Industrial fieldbus
High-current output

High-current output

High-current output

INTERFACES

SR ZERO - SR ZERO A

SR ZERO - SR ZERO A

2 NO + 1 NC
2 NO
SR ONE - SR ONE M

SR ONE - SR ONE M

2 NO
2 NO - Muting function
SR E4  - SR E4 C

SR E4 - SR E4 C

2 NO - Automatic/manual restart
2 NO - Manual restart
SR T

SR T

2 NO
SR X - SR XM

SR X - SR XM

2 NO
2 NO - Muting function

FASTENING

FASTENING

DIN RAIL

TERMINAL BLOCKS

TERMINAL BLOCKS

Screws, Clamps

FASTENING

FASTENING

DIN RAIL

TERMINAL BLOCKS

TERMINAL BLOCKS

Screws, Clamps

FASTENING

FASTENING

DIN RAIL

TERMINAL BLOCKS

TERMINAL BLOCKS

Screws, Clamps

SAFETY LEVEL

SAFETY LEVEL

PL e - SILCL 3 - Cat. 4

IP RATING

IP RATING

IP20

SAFETY LEVEL

SAFETY LEVEL

PL e - SILCL 3 - Cat. 4

IP RATING

IP RATING

IP20

SAFETY LEVEL

SAFETY LEVEL

PL e - SILCL 3 - Cat. 4

IP RATING

IP RATING

IP20